PV MANUFACTURING EQUIPMENT
My account中国工厂入驻 Create RFQ

EQUIPMENT MODEL

HL-KZPCNS-HO · Automatic TOPCon laser doping machine

Hymson Laser Technology Group Co., Ltd. ↗

Hymson's HL-KZPCNS-HO dopes TOPCon wafers by laser through the borosilicate glass layer, with vision positioning and automatic wafer transport. Choose it by your wafer condition and process target. Hymson speaks of lossless doping and higher productivity; your own sample run sets the acceptance result.

Covers the named model HL-KZPCNS-HO. The English overview omits some numerical fields, so request the current model sheet.

General illustration of cell production equipment, not a photograph of this model. Ask the manufacturer for current photographs and layout drawings of the configuration offered.

START WITH YOUR PRODUCTION TASK

Quote 182 mm and 210 mm throughput as two separate cases. Before ordering, ask Hymson to confirm in writing the BSG and wafer input it assumes and the process measurements used for acceptance.

SOURCE-LINKED DATA

Published specifications

Values below are published by the manufacturer, each with the date its source was checked. Ask for the figures that apply to your configuration and material in the quotation.

Manufacturer catalogue values
ParameterPublished valueSource check
Alignment accuracy±15 µm2026-09-26
Wafer sizes166, 182, 210 and 230 mm2026-09-26
182 mm wafer throughputAt least 8400 pcs/h with fewer than 132 grid lines2026-09-26

See sources and check dates ↓

01 · PVYard procurement analysis

What to send Hymson first

  • BSG and wafer preparation

    Hymson uses BSG as the doping source. Send your wafer preparation route and process targets so Hymson can match a recipe and say where its step begins and ends.

  • Wafer format and handling

    The machine positions wafers by vision and moves them on its own transport. Give the format, thickness and incoming condition, then check placement accuracy and handling damage in one trial.

  • Listed wafer sizes

    Hymson lists 166, 182, 210 and 230 mm wafers. Name the size you run so the quote uses the matching throughput case.

Source: Hymson HL-KZPCNS-HO product page

02 · PVYard procurement analysis

Three results to measure on their own

Three results to measure on their own
ResultYour process team setsHymson provides
Doping resultThe target for the treated wafer and how it is measured.Sample results linked to the wafer input and recipe used.
Alignment and transportReference datum, handling path and defect classes.Position and handling records from the sample wafers.
Accepted outputThe 182 mm, 210 mm or other format and the length of the run.Output, rejects and stops for that format on the first pass.

Source: Hymson HL-KZPCNS-HO product page

03 · PVYard procurement analysis

Match the model to the current offer

Name HL-KZPCNS-HO in your first message and check that Hymson still offers that model or an older catalogue name. Keep each throughput figure attached to its wafer format and ask for the current sheet under revision control. The English overview explains the process but leaves out the table you need to compare machines.

Set the sample plan before discussing performance guarantees. Measure the doping result apart from positioning accuracy and breakage. Ask Hymson how it defines each measure, which wafers it uses and which settings it records. Any yield or conversion-efficiency gain should be read from those sample results.

Source: Hymson HL-KZPCNS-HO product page

04 · PVYard procurement analysis

TOPCon doping enquiry checklist

  • Model and drawing

    Request the model now offered, its technical sheet and a configuration drawing.

  • Wafer and BSG

    Send format, thickness and your real input and process requirements.

  • Trial criteria

    Agree doping measurements, alignment and damage limits on representative wafers.

  • Throughput per format

    Ask for a separate throughput condition for each wafer format you plan to run, with accepted output and stops stated.

Source: Hymson HL-KZPCNS-HO product page

TURN THIS INTO A CLEAR REQUEST

Ask about this product

Include the product-specific questions above and replace every bracket with your actual requirement. Save your edited text to your sourcing brief, then review it before submitting an enquiry. Saving a brief does not send it to a manufacturer.

Sources

Manufacturer information and our buying guidance are labelled section by section above. Each source below shows the date it was checked.

Hymson HL-KZPCNS-HO product page ↗

Source check: 2026-10-11 · Hymson's process description, wafer sizes and throughput conditions for this model.

Report a correction · How we prepare listings

Analytics preferences

Allow optional audience measurement? Your choice can be changed in the footer. Essential account cookies remain necessary for sign-in and forms.