EQUIPMENT SERIES
Ideal Energy PV wafer wet-process family
Ideal Energy (Shanghai) Sunflower ↗A wet-chemistry line for solar wafers with tanks built to order, physically separated acid and alkaline zones and self-cleaning exhaust ducts.
Based on Ideal Energy's wet-process product page. Bath recipe, wafer thickness limit, breakage rate, tank size, cycle time and the environmental and utility table come with a quote for your process.
General illustration of cell production equipment, not a photograph of this model. Ask the manufacturer for current photographs and layout drawings of the configuration offered.
START WITH YOUR PRODUCTION TASK
Approve the wafer, carrier and surface targets, fix the tank, robot and exhaust layout, and accept on surface results, contamination and handling with your own chemistry. Ask Ideal Energy to confirm in writing the supported wafer thickness and the cleaning intervals.
SOURCE-LINKED DATA
Published specifications
Values below are published by the manufacturer, each with the date its source was checked. Ask for the figures that apply to your configuration and material in the quotation.
The manufacturer has not published a complete specification table for this entry. Request the exact offered drawing and operating limits.
01 · Manufacturer information
Tank layout and acid/alkali separation
The line takes 182R–210R wafers. Tank count, layout and function are built to the customer's process. Extraction covers the whole line, acid and alkaline regions are hard-separated, and robots distribute wafers so the two chemistries stay apart. The format codes give no full width, length and thickness, so send your wafer drawing.
Cleaning baths circulate continuously, with flow set by a variable-frequency drive. Extraction ducts on the alkaline modules have a hot-water flush to stop alkaline crystals building up. Cleaning intervals, water quality, exhaust flow and contamination results are not listed. Ask for them and check they fit your site systems.
02 · Manufacturer information
Wet line features and order details
| Feature | Ideal Energy lists | Define in the order |
|---|---|---|
| Wafer formats | 182R–210R | Drawing, thickness, carrier and handling limits. |
| Tanks | Number, layout and functions to order | Bath sequence and station functions. |
| Acid and alkali zones | Hard separation, robot distribution | Physical, exhaust and carryover interfaces. |
| Circulation | Flow set by variable-frequency drive | Flow, filtration and cleanliness targets. |
| Alkaline exhaust | Hot-water duct cleaning | Water, drain and exhaust match, plus service steps. |
03 · PVYard procurement analysis
What to send for a wet-line quotation
Wafers and surface
R-format dimensions, thickness, incoming surface and the texture, cleanliness and electrical results you need. Include carriers and breakage limits.
Baths and transport
Approved chemistry, bath order, process conditions and allowed carryover. Ask for the tank and robot layout and the materials in contact with each chemical.
Utilities and service
Chemical supply, exhaust, water, drain and waste-treatment hook-ups for your process. Settle duct cleaning, service access and operating safety duties.
04 · PVYard procurement analysis
Wet line acceptance steps
Approve layout and chemistry
Fix wafer and carrier, tank functions, robot routes and the bath and site package.
Check surfaces and breakage
Measure surface results and wafer damage or breakage over representative loads, with inputs and conditions logged.
Test separation and cleaning
Check carryover and contamination limits and run the exhaust-cleaning procedure against set criteria.
Run, fault and recover
Measure accepted output on the approved sequence. Then simulate tired or abnormal baths, transfer faults and restart rejects, and file the service instructions.
05 · PVYard procurement analysis
Ideal Energy wet-process questions
Does 182R–210R tell me the wafer thickness?
No. It names the formats only. Send your drawing and run a handling trial.
Does hard separation mean zero cross-contamination?
Ideal Energy gives no numeric result. Set limits for baths, carriers and exhaust and test them.
Can I drop in a standard texture recipe?
The page offers no universal bath recipe. Build the sequence around your own cell process with Ideal Energy. Once wafers leave the wet line textured and clean, the next deposition step in Ideal Energy's range is its PECVD family.
TURN THIS INTO A CLEAR REQUEST
Ask about this product
Include the product-specific questions above and replace every bracket with your actual requirement. Save your edited text to your sourcing brief, then review it before submitting an enquiry. Saving a brief does not send it to a manufacturer.
Sources
Manufacturer information and our buying guidance are labelled section by section above. Each source below shows the date it was checked.
Ideal Energy wet-process product page ↗
Source check: 2026-10-11 · Wafer formats, tank options, acid/alkali separation and duct cleaning.
Compare equipment for a related task