PV MANUFACTURING EQUIPMENT
My account中国工厂入驻 Create RFQ

COMPONENT

JS-606 PLUS · JS-606 PLUS PV frame and box bonding sealant

Hangzhou Zhijiang Silicone Chemicals ↗

JS-606 PLUS is an oxime-cure silicone that Zhijiang sells for bonding PV aluminium frames and junction boxes. Plan around your real joint, surfaces and handling sequence. Box potting uses Zhijiang's JS-1184 family instead.

The figures below are Zhijiang's lab data for JS-606 PLUS. Your line recipe, handling time, module ageing result and the current grade certificate come from your own trial and from Zhijiang's document package.

General illustration of module assembly equipment, not a photograph of this model. Ask the manufacturer for current photographs and layout drawings of the configuration offered.

START WITH YOUR PRODUCTION TASK

Define the joint and substrates, get the current grade and safety documents, then prove surface preparation, dispensing, cure and adhesion under logged production conditions.

SOURCE-LINKED DATA

Published specifications

Values below are published by the manufacturer, each with the date its source was checked. Ask for the figures that apply to your configuration and material in the quotation.

The manufacturer has not published a complete specification table for this entry. Request the delivered material specification, drawing where applicable and lot acceptance requirements.

See sources and check dates ↓

01 · Manufacturer information

Where JS-606 PLUS goes on a module

  • Frame bonding

    Zhijiang lists PLUS for bonding and sealing PV aluminium frames. Bring the frame coating, laminate edge and joint drawing to the first meeting so preparation and bead size can be chosen.

  • Junction-box attachment

    PLUS also fixes junction boxes, and the page names composite backsheet and PPO among its substrates. Check adhesion on your own backsheet treatment; filling the box is a potting job for another grade.

  • Sister grades

    PLUS cures by oxime release, CHUN by alcohol release, and D is a two-part grade mixed 1:1. Each has its own cure data and dispensing rules.

Sources: JS-606 PLUS product pageZhijiang PV solutions page

02 · Manufacturer information

Dispensing and cure figures

Dispensing and cure figures
PropertyIndexTypicalMethod or condition
ColourWhite or blackWhiteVisual.
Density1.47±0.03 g/cm³1.47 g/cm³GB/T 13477-2002.
Tack-free time5–15 min8 minGB/T 13477, as listed.
Extrusion time10–20 s per 20 g17 s per 20 g3 mm nozzle at 0.5 MPa.
Cure depth, 4 h≥1.00 mm1.05 mmGB/T 29595-2013.
Cure depth, 24 h≥2.0 mm2.6 mmSame cure-depth method.

Source: JS-606 PLUS product page

03 · Manufacturer information

Cured properties

Cured properties
PropertyIndexTypicalMethod
Shore A hardness45–6560GB/T 531-2008.
Tensile strength≥2.8 MPa3.0 MPaGB/T 528-2009.
Elongation at break≥250%300%GB/T 528-2009.
Al–Al shear strength≥2.0 MPa2.5 MPaGB/T 7124, as listed.
Volume resistivity≥1.0 × 10¹⁴ Ω·cm1.2 × 10¹⁵ Ω·cmGB/T 1692, as listed.
Dielectric strength≥15 kV/mm18 kV/mmGB/T 1695, as listed.

Source: JS-606 PLUS product page

04 · PVYard procurement analysis

Line trial for bead and surface preparation

  1. Fix surfaces and joint size

    Write down the aluminium coating, glass, backsheet and box materials, any treatment, the gap and the bead drawing. Ask Zhijiang for compatibility and adhesion guidance on that exact set.

  2. Approve cleaning and safety data

    Zhijiang names some solvents as examples. Get the current SDS and confirm with Zhijiang and your equipment maker which solvent, wipe routine and primer, if any, suit your parts.

  3. Log the dispensing run

    Use a traceable PLUS lot on your own dispenser. Note bead size, nozzle, room temperature and humidity and the machine settings. The 20 g lab extrusion figure describes flow, while line output depends on your equipment.

  4. Set handling and cure release

    Decide when the module may be moved and what cure and adhesion results release it. Load-bearing strength is measured on the joint; a tack-free surface and catalogue cure depth are early signs only.

  5. Keep ageing and change records

    Agree module-stack and environmental tests with engineering. Store approved samples and records, and review any change in formula, substrate, equipment or pack before the next production run.

Sources: JS-606 PLUS product pageZhijiang PV solutions page

05 · Manufacturer information

Temperature range, ageing tests and the standard plan

Zhijiang states a service range of −40 to 180°C and says PLUS passed double-85, ageing and thermal cycling tests. Durations, cycle counts and specimen build are missing from the web page. Ask for the full test report and, if possible, results on a joint like yours.

Zhijiang is named as a drafter in consultation-stage plan 20253706-T-606 for PV silicone sealants. The revised standard has not yet been published. For your order, ask for the certificates PLUS holds today, and agree warranty terms and expected service life in the contract.

Sources: JS-606 PLUS product pagePV sealant standard revision plan

06 · PVYard procurement analysis

Packs, storage and what to put in the quotation request

  • Grade and colour

    Order JS-606 PLUS by its controlled revision and pack label, in white, black or a custom colour if Zhijiang offers one.

  • Pack and dispenser

    Zhijiang lists 310 mL cartridges, 400 mL soft packs, five-gallon plastic pails and 55-gallon steel drums. Match the pack to your dispensing equipment and order size.

  • Storage and shelf life

    Zhijiang specifies cool, dry storage and a 12-month shelf life. Ask for the storage temperature, sealed and opened handling and dates of manufacture and expiry on each lot.

  • Documents

    Current TDS, SDS, certificate annex and adhesion instructions, sent through Zhijiang's normal channel with the quote.

  • Trial and release terms

    Attach the joint drawing, substrates and the acceptance tests you need. Agree lot traceability, lead time, price and change notice.

Sources: JS-606 PLUS product pageZhijiang PV solutions page

07 · PVYard procurement analysis

Buyer questions on JS-606 PLUS

Can I move the module after eight minutes?

Eight minutes is the typical tack-free time in the lab. Handling time for your joint comes from your own line trial.

Can PLUS replace potting compound inside the box?

PLUS is sold for bonding and sealing. Zhijiang offers the JS-1184 family for potting.

Does the catalogue photo show a PLUS pack?

The image carries the JS-606 family label. Ask for a photo of the PLUS pack and its shipping label.

Which column goes in my specification?

The index column sets limits and the typical column shows example lab results. Agree the order specification and test methods with Zhijiang.

How do I get the full TDS?

The PDF downloads after a member or contact sign-up on Zhijiang's site, or you can ask your Zhijiang contact to send it.

Sources: JS-606 PLUS product pageZhijiang PV solutions pageJS-606 family image

TURN THIS INTO A CLEAR REQUEST

Ask about this product

Include the product-specific questions above and replace every bracket with your actual requirement. Save your edited text to your sourcing brief, then review it before submitting an enquiry. Saving a brief does not send it to a manufacturer.

Sources

Manufacturer information and our buying guidance are labelled section by section above. Each source below shows the date it was checked.

JS-606 PLUS product page ↗

Source check: 2026-10-11 · Index and typical columns with lab conditions; full TDS PDF on member sign-up.

Zhijiang PV solutions page ↗

Source check: 2026-10-11 · Oxime, alcohol-release, two-part and potting grades by job.

PV sealant standard revision plan ↗

Source check: 2026-10-11 · Consultation-stage plan naming Zhijiang as a drafter.

JS-606 family image ↗

Source check: 2026-10-11 · Pack artwork labelled JS-606.

Report a correction · How we prepare listings

Analytics preferences

Allow optional audience measurement? Your choice can be changed in the footer. Essential account cookies remain necessary for sign-in and forms.