PV MANUFACTURING EQUIPMENT
My account中国工厂入驻 Create RFQ

COMPONENT

H1Z2Z2-K · H1Z2Z2-K PV cable component family

Ningbo Qrunning Cable ↗

Qrunning's H1Z2Z2-K is a single-core PV cable for module leads and DC wiring. The catalogue lists it separately from PV1-F, so pick the construction and the approved termination along with the voltage.

This listing covers the cable itself. Installation design, cable-making machinery and connector kits come from other suppliers, and ampacity and connector mating need their own data.

General illustration of module assembly equipment, not a photograph of this model. Ask the manufacturer for current photographs and layout drawings of the configuration offered.

START WITH YOUR PRODUCTION TASK

Pick the designation and section, get controlled dimensions and the rating documents, then prove the contact, seal and joining process on traceable samples.

SOURCE-LINKED DATA

Published specifications

Values below are published by the manufacturer, each with the date its source was checked. Ask for the figures that apply to your configuration and material in the quotation.

The manufacturer has not published a complete specification table for this entry. Request the delivered material specification, drawing where applicable and lot acceptance requirements.

See sources and check dates ↓

01 · Manufacturer information

H1Z2Z2-K and PV1-F side by side

H1Z2Z2-K and PV1-F side by side
DesignationSingle-core sectionAC ratingDC rating and condition
PV1-F1.5–35 mm²0.6/1 kV U0/U1.8 kV conductor to conductor; unearthed system; no circuit load.
H1Z2Z2-K1.5–240 mm²1.0/1.0 kV U0/U1.5 kV conductor to conductor; unearthed system; no circuit load.

Source: Qrunning PV cable catalogue (Chinese)

02 · Manufacturer information

Ambient, conductor and fault temperatures are three different limits

Ambient, conductor and fault temperatures are three different limits
ConditionCatalogue figureAsk Qrunning
Ambient temperature−40…90°CWhich standard and environmental tests back this range?
Normal conductor maximum120°CWhich designation, duration and rating basis apply? This is a conductor figure.
Short circuit200°C; no longer than 5 secondsHow does it fit your fault protection? It applies to faults only.
Laying temperatureAmbient not below 0°CHandling instructions for the cable as delivered.
Bend radiusAt least 6 × cable outer diameterOuter diameter of your section and any assembly bend rules.

Source: Qrunning PV cable catalogue (Chinese)

03 · Manufacturer information

Standards listed and the certificate to request

Qrunning cites 2Pfg1169/08:2007 and EN 50618:2014 for its PV cable. Ask for the certificate that covers your order: standard edition, certificate holder, producing site, model and the annex listing approved sections.

The laboratory page lists resistance, mechanical, ageing and flame tests. Its insulation-resistance method covers sections up to 120 mm². For sections above that, up to the 240 mm² catalogue limit, and for terminated leads, ask how Qrunning tests them and who issues the report.

Sources: Qrunning PV cable catalogue (Chinese)Qrunning laboratory methods

04 · Manufacturer information

What the cross-section drawing shows

  • Conductor

    The centre is labelled conductor. Copper grade, strand count, tinning and DC resistance go on the controlled construction sheet you request.

  • Insulation

    The middle ring is labelled insulation. Thickness tolerance and compound name belong in the order specification.

  • Sheath

    The outer ring is the sheath. Get its diameter and material for your section, because they decide seal fit and handling.

Sources: Cable cross-section illustrationQrunning PV cable catalogue (Chinese)

05 · PVYard procurement analysis

Prove the cable-to-contact joint before volume orders

  1. Choose the real parts

    List designation, section, strand build and outer diameter next to the exact connector, contact and junction box. Have both suppliers approve that combination.

  2. Agree preparation and joining

    Get strip length, tool identity, crimp or joining instructions, seal position and inspection rules. Use the tooling the contact maker approves for this cable.

  3. Test traceable samples

    Set dimensional, mechanical, electrical and environmental checks with engineering. Log the reel, contact and box lots, tools and settings for every sample.

  4. Carry approval into production

    Tie later reels to the approved sample and test plan. Requalify if stranding, compound, diameter, tooling or plant changes.

Sources: Qrunning PV cable catalogue (Chinese)Qrunning laboratory methods

06 · PVYard procurement analysis

Items for your H1Z2Z2-K quotation request

  • Construction

    Section, conductor requirements, colour, marking and dimensional tolerances.

  • Ratings and certificate

    Full AC and DC conditions, temperature definitions, the current certificate and its model and site annex.

  • Termination data

    Connector, contact and junction box names, permitted seal diameter and controlled joining steps.

  • Reel documents

    Reel length and tolerance, lot number, resistance and dimension report, and the sampling plan.

  • Commercial terms

    MOQ, lead time, packing, storage and change notice, with stock and price stated in the quote.

Sources: Qrunning PV cable catalogue (Chinese)Qrunning laboratory methods

07 · Manufacturer information

Need rodent or UV resistance? Ask for the released grade

A flexible cable that stands up to rodents, ants and UV is still a project under way in Qrunning's 2025 report. Standard H1Z2Z2-K reels are listed without those properties. If your site needs them, ask for the released designation, its construction and the matching test reports.

Source: Qrunning 2025 annual report

08 · PVYard procurement analysis

Buyer questions on H1Z2Z2-K

Where do I find ampacity?

The catalogue gives sections only. Ask Qrunning for a current-carrying table for your installation method and temperature.

Can the cable run at 200°C?

No. 200°C is the short-circuit limit, for five seconds at most.

What bend radius in millimetres?

The rule is at least six times the outer diameter. Multiply by the diameter of the section you order.

Is the drawing my reel?

It is a layer sketch with no grade, section, dimensions or reel number. Your reel is defined by the construction sheet and test report.

Can I use any connector rated for the same section?

Ask the connector maker and Qrunning to approve the exact contact, strain relief and seal combination for this cable.

Sources: Qrunning PV cable catalogue (Chinese)Qrunning laboratory methodsCable cross-section illustration

TURN THIS INTO A CLEAR REQUEST

Ask about this product

Include the product-specific questions above and replace every bracket with your actual requirement. Save your edited text to your sourcing brief, then review it before submitting an enquiry. Saving a brief does not send it to a manufacturer.

Sources

Manufacturer information and our buying guidance are labelled section by section above. Each source below shows the date it was checked.

Qrunning PV cable catalogue (Chinese) ↗

Source check: 2026-10-11 · Section table, voltage rows and use conditions for both designations.

Qrunning laboratory methods ↗

Source check: 2026-10-11 · Test methods with their section and material limits.

Qrunning 2025 annual report ↗

Source check: 2026-10-11 · Lists the rodent, ant and UV resistant cable as a project in progress.

Cable cross-section illustration ↗

Source check: 2026-10-11 · Layer sketch of conductor, insulation and sheath.

Report a correction · How we prepare listings