PV MANUFACTURING EQUIPMENT
My account中国工厂入驻 Create RFQ

COMPONENT

F406P / F406PS normal EVA encapsulation film

Hangzhou First Applied Material Co., Ltd. ↗

F406P and F406PS are the UV-transmitting pair in FIRST's normal EVA encapsulant series. FIRST publishes one data column for both, so order by exact suffix with its own technical sheet.

A consumable for PV module production, supplied as encapsulant film. FIRST lists normal-series uses as PERC front and rear and TOPCon rear. For front-side TOPCon or HJT, ask FIRST which grade it recommends.

General illustration of module assembly equipment, not a photograph of this model. Ask the manufacturer for current photographs and layout drawings of the configuration offered.

START WITH YOUR PRODUCTION TASK

Settle the suffix and module side first. Then ask FIRST to confirm in writing the roll sizes, storage terms and a laminating window for your machine. Use the published values to shortlist the film, and qualify the finished module with your own trials.

SOURCE-LINKED DATA

Published specifications

Values below are published by the manufacturer, each with the date its source was checked. Ask for the figures that apply to your configuration and material in the quotation.

The manufacturer has not published a complete specification table for this entry. Request the delivered material specification, drawing where applicable and lot acceptance requirements.

See sources and check dates ↓

01 · Manufacturer information

Which F406 suffix, and which side of the module

FIRST lists F406P and F406PS as UV-transmitting grades in its normal EVA series. Their counterparts, F806P and F806PS, are the UV-cutoff grades. FIRST names PERC front and rear and TOPCon rear as the uses. Keep the grade name, cell type and module side on your enquiry; a bare request for solar EVA loses the spectral choice.

One data column covers both F406P and F406PS, and FIRST states no difference between them. Ask for the exact suffix, its current technical data sheet and confirmation for your module position. The roll pictured on the catalogue page is FIRST's general EVA artwork rather than a labelled F406 sample.

Source: FIRST normal EVA series with the shared F406P/F406PS table

02 · Manufacturer information

F406P / F406PS published values and test references

F406P / F406PS published values and test references
PropertyF406P / F406PS columnPublished reference or condition
Transmission, 1100–380 nm≥91%GB/T 29848-2018
Transmission, 380–290 nm≥80%GB/T 29848-2018
VA content28±2%GB/T 29848-2013 as printed
Gel content≥75 Gel%GB/T 29848-2018
Volume resistivity≥1.0×10¹⁵ Ω·cmGB/T 29848-2018
Dielectric strength≥28.0 kV/mmGB/T 29848-2018
CTI≥600 VGB/T 29848-2018
Peel from glass≥60 N/cmGB/T 29848-2018
Peel from backsheet≥40 N/cmISO 8510-2:1990
Tensile strength≥16 MPaCured film; GB/T 29848-2018
Elongation at break≥450%Cured film; GB/T 29848-2018
Shrinkage, MD / TD≤3.0% / ≤1.5%GB/T 29848-2018

Source: FIRST normal EVA series with the shared F406P/F406PS table

03 · PVYard procurement analysis

Reading the F406 numbers for a module build

  • Film electrical values and module ratings

    Volume resistivity, dielectric strength and CTI are three separate film tests. A module voltage rating, a PID result or a stack certificate each needs its own test report, so request the ones your module requires.

  • Glass peel and backsheet peel

    FIRST gives ≥60 N/cm to glass and ≥40 N/cm to backsheet, under different references. Tell FIRST your glass coating or backsheet surface and test your own production surfaces.

  • Cured film figures

    Tensile strength and elongation are quoted for cured film. Handling rules for the uncured roll and the curing time come from the technical sheet. The gel-content minimum tells you the target; the laminator temperature and dwell that reach it come from trials.

  • Shrinkage in two directions

    Machine direction allows up to 3.0% and transverse direction up to 1.5%. Keep both on your drawing and sample plan, get the test conditions, and check layup and alignment against each one.

Sources: FIRST normal EVA series with the shared F406P/F406PS tableNational standards database: GB/T 29848-2018

04 · PVYard procurement analysis

Two points in the FIRST table to settle with the sales team

VA content cites GB/T 29848-2013, while most other rows cite the 2018 edition. The national standards database shows that the 2018 edition replaced 2013. Ask FIRST which method and edition apply to the current grade and to your shipment.

The F806P/F806PS column shows the same short-wavelength transmission value as the F406 pair, although FIRST calls the F806 grades UV-cutoff. If you are choosing between the two pairs, ask for a corrected spectral sheet with the wavelength range and FIRST's advice on front or rear use.

Sources: FIRST normal EVA series with the shared F406P/F406PS tableNational standards database: GB/T 29848-2018

05 · PVYard procurement analysis

Setting up a laminating trial with F406 film

  1. Name the materials and position

    Give FIRST the F406 suffix, cell technology, front and rear build, surfaces and interconnect layout. Ask for its recommended use for that exact build.

  2. Set roll and storage terms

    Ask for thickness and tolerance, width, roll length, lot number, packing, storage temperature and humidity, shelf life and the time allowed after opening. The shared data table lists none of these.

  3. Get a laminating window

    Share your laminator model and cycle limits, then ask for temperature, vacuum, pressure and dwell guidance and the method for checking cure. Treat the gel-content minimum as the target your recipe must reach.

  4. Agree sample and module acceptance

    Tie adhesion, cure, optical and electrical checks to your stack and qualification plan. Record each sample, its conditioning and the results. Agree that any change of suffix, formula or plant needs your approval first.

Source: FIRST normal EVA series with the shared F406P/F406PS table

06 · PVYard procurement analysis

Questions before ordering F406P or F406PS

How do F406P and F406PS differ?

The table groups them and gives no suffix-specific process notes. Ask FIRST for the current individual sheet and its recommendation for your module.

Is F406 listed for front-side TOPCon or HJT?

The normal-series uses are PERC front and rear and TOPCon rear. For other cell types or positions, ask FIRST to confirm the grade in writing.

Does FIRST publish laminator settings?

The table gives no temperature, vacuum, pressure or dwell values. Ask for process guidance and prove it on your own laminator and stack.

Is the pictured roll an F406 lot?

It is FIRST's general EVA artwork. Grade, thickness, lot number and test papers should arrive with the quote and with each delivery.

What should FIRST confirm in writing before I order?

The suffix and its sheet, roll sizes and storage terms, a laminating window, the quoting entity and the plant that makes your film. Long-term module performance comes from your own qualification tests.

Sources: FIRST normal EVA series with the shared F406P/F406PS tableNational standards database: GB/T 29848-2018

TURN THIS INTO A CLEAR REQUEST

Ask about this product

Include the product-specific questions above and replace every bracket with your actual requirement. Save your edited text to your sourcing brief, then review it before submitting an enquiry. Saving a brief does not send it to a manufacturer.

Sources

Manufacturer information and our buying guidance are labelled section by section above. Each source below shows the date it was checked.

FIRST normal EVA series with the shared F406P/F406PS table ↗

Source check: 2026-10-11 · Shared data column and listed applications for the pair; no separate suffix sheet or full process conditions.

National standards database: GB/T 29848-2018 ↗

Source check: 2026-10-11 · The 2018 edition replaced 2013; FIRST's table still cites 2013 for VA content.

Report a correction · How we prepare listings

Analytics preferences

Allow optional audience measurement? Your choice can be changed in the footer. Essential account cookies remain necessary for sign-in and forms.