PV MANUFACTURING EQUIPMENT
My account中国工厂入驻 Create RFQ

EQUIPMENT SERIES

HORAD module label-verification station

Suzhou HORAD New Energy Equipment Co., Ltd. ↗

Cylinders align and stop each module, then scanners and a camera check three labels: the front barcode, the frame code and the nameplate.

HORAD lists the three labels, the camera defect types, panel sizes, utilities and machine size. Code types, read grades, position limits, cross-checks between codes, detection rates and data storage are not given. It sits with the testing and inspection stations near the end of the line.

General illustration of testing & inspection equipment, not a photograph of this model. Ask the manufacturer for current photographs and layout drawings of the configuration offered.

START WITH YOUR PRODUCTION TASK

Use it as the gate after labeling. Give HORAD all three layouts with expected values, agree which defects the camera must catch, and run wrong, missing, unreadable and shifted labels through it before you accept.

SOURCE-LINKED DATA

Published specifications

Values below are published by the manufacturer, each with the date its source was checked. Ask for the figures that apply to your configuration and material in the quotation.

The manufacturer has not published a complete specification table for this entry. Request the exact offered drawing and operating limits.

See sources and check dates ↓

01 · Manufacturer information

What the scanners and camera look at

Cylinders align the module and a stop holds it in place. Barcode scanners and cameras then read the front barcode, the frame code and the nameplate. The camera also spots a missing nameplate, print defects and labels placed off position.

HORAD does not say whether the three codes are compared with each other or with the production record. No barcode grade, position limit in millimetres or measured catch rate is listed either. Write three separate pass rules into the order: the code reads, the label looks right, and the serial belongs to that module. Modules that pass can then go on to HORAD's grade-driven sorting system, which relies on the same serial being right.

Source: HORAD auto label verification page

02 · Manufacturer information

Listed figures for the verification station

Listed figures for the verification station
ItemHORAD listsPass rule to write
Labels checkedFront barcode, frame code, nameplateYour labels, code formats and which codes must match.
Camera defectsPresence, print defects, placement deviationsDefect catalogue, limits and the samples behind them.
Panel sizes1650 × 990–2500 × 1400 mmFormats you run and whether each label is in camera view.
Supply / power / airAC380 V / 0.5 kW / 0.6–0.8 MPaSmall electrical draw; confirm air use for the stop cylinders.
Machine size, L × H × W / weight2800 × 1600 × 1200 mm / 0.3 TLighting, guarding and access for cleaning optics.

Source: HORAD auto label verification page

03 · PVYard procurement analysis

Build a sample set with known answers

  • Codes

    List symbologies, content, contrast and print rules, and the value each label should hold. Agree what happens on a no-read or a doubtful read.

  • Label appearance

    Collect real examples of missing or torn nameplates, smudged print and shifted labels, measured, so the camera limits rest on samples.

  • Serial match and logging

    If codes must match each other or the production record, say so, along with how pass and fail results are kept. Scanners and a camera on the frame do not set this up by themselves.

Source: HORAD auto label verification page

04 · PVYard procurement analysis

Testing each way a label can fail

  1. Freeze labels and rules

    Fix the three layouts, code formats, matching rules and defect limits.

  2. Show it bad labels

    Run missing, defective and shifted labels on every format and compare each scanner and camera call with the known answer.

  3. Show it wrong serials

    If matching is in scope, feed readable but wrong codes, duplicates and codes that disagree with the record. Score these apart from read success.

  4. Lose a result

    Force a no-read, drop a result and interrupt a transfer. Check that failed modules are set aside, can be rechecked, and that the first module after any change is inspected.

Source: HORAD auto label verification page

05 · PVYard procurement analysis

Questions about label verification

If the barcode reads, is it the right one?

Not necessarily. Catching a wrong serial needs a rule that compares the code with the expected value.

What position tolerance does the camera hold?

HORAD gives no number. Set the allowed label position and how it is measured in the order.

Are results sent to the factory system?

HORAD does not describe a data link. Ask what interface is offered and how long results are kept.

Source: HORAD auto label verification page

TURN THIS INTO A CLEAR REQUEST

Ask about this product

Include the product-specific questions above and replace every bracket with your actual requirement. Save your edited text to your sourcing brief, then review it before submitting an enquiry. Saving a brief does not send it to a manufacturer.

Sources

Manufacturer information and our buying guidance are labelled section by section above. Each source below shows the date it was checked.

HORAD auto label verification page ↗

Source check: 2026-10-11 · Three checked labels, scanner and camera roles, panel range, utilities and machine size.

Report a correction · How we prepare listings

Compare equipment for a related task

These entries are in the same category; check each one's specifications and configuration.

Analytics preferences

Allow optional audience measurement? Your choice can be changed in the footer. Essential account cookies remain necessary for sign-in and forms.