PV MANUFACTURING EQUIPMENT
My account中国工厂入驻 Create RFQ

EQUIPMENT SERIES

NWSS-250 and 250A 25-block polycrystal cropping family

TDG NISSIN ↗

A head-and-tail cropper for 25 polycrystalline silicon blocks per load, built in two versions, NWSS-250 and NWSS-250A, which share one data sheet.

Both versions run 0.31–0.33 mm coated diamond wire at up to 900 m/min with 0–80 N tension. They differ in wheel lift, power, size and weight. The sheet lists 156 × 156 × 300 mm blocks, while the product page text says 400 mm.

General illustration of wafer processing equipment, not a photograph of this model. Ask the manufacturer for current photographs and layout drawings of the configuration offered.

START WITH YOUR PRODUCTION TASK

Pick this family if you crop 25 polysilicon blocks at a time. Fix your incoming block length and end allowance first, then ask TDG NISSIN to quote the 250 and the 250A on the same sample stock, each with its own fixture, lift and site package.

SOURCE-LINKED DATA

Published specifications

Values below are published by the manufacturer, each with the date its source was checked. Ask for the figures that apply to your configuration and material in the quotation.

The manufacturer has not published a complete specification table for this entry. Request the exact offered drawing and operating limits.

See sources and check dates ↓

01 · Manufacturer information

What the NWSS-250 family does

The NWSS-250 crops the head and tail ends from 25 polycrystalline blocks in a single load, using diamond multiwire. TDG NISSIN builds it as the NWSS-250 and the NWSS-250A and prints both columns next to each other on one data sheet. For larger batches, the maker's large-batch polycrystal cropper is the next size up.

The two share wire size, wire speed, tension, water and air figures. The 250 has the longer wheel lift, 450 mm at up to 450 mm/min, and draws 27 kW. The 250A lifts 350 mm at up to 350 mm/min and draws 35 kW. The 250A is also longer, wider and taller, yet the sheet gives it the lower mass, 9000 kg against 10000 kg.

Block length is the point to settle before a quote. The product page text speaks of 400 mm blocks, while both sheet columns list 156 × 156 × 300 mm × 25. The photo shows the family in general, so ask which version it pictures and how fixtures and handling differ between the two.

Sources: TDG NISSIN product page: 25-block polysilicon cropperNWSS-250 / NWSS-250A data sheet

02 · Manufacturer information

NWSS-250 and NWSS-250A side by side

NWSS-250 and NWSS-250A side by side
ItemNWSS-250NWSS-250A
Stock on the sheet156 × 156 × 300 mm × 25156 × 156 × 300 mm × 25
Coated wire / spool0.31–0.33 mm; up to 1.2 km at 0.33 mmSame as NWSS-250
Wire speed / tensionUp to 900 m/min; 0–80 N900 m/min; 0–80 N
Wheel lift450 mm; 0–450 mm/minUp to 350 mm; 0–350 mm/min
Water0.2–0.3 MPa; 200 L/min0.2–0.3 MPa; 200 L/min
Air0.6–0.7 MPa; up to 30 m³/hSame as NWSS-250
PowerAC 380 V, 50 Hz; 27 kWAC 380 V, 50 Hz; 35 kW
Size L × W × H3570 × 1735 × 2500 mm3850 × 2100 × 2850 mm
Mass10000 kg9000 kg

Sources: TDG NISSIN product page: 25-block polysilicon cropperNWSS-250 / NWSS-250A data sheet

03 · PVYard procurement analysis

Ask TDG NISSIN to confirm in writing

  • Which version

    Name NWSS-250 or NWSS-250A in the quotation and request the fixture, lift and material-handling drawing for it. The family photo is a general picture of both.

  • 300 or 400 mm blocks

    Have the incoming block length stated on a controlled drawing, together with the end allowance you may take off each block. The blocks usually come from a cast block divided into columns on a batch diamond-wire squarer.

  • Cut quality

    Write down the length you keep, end-face geometry, chip and crack limits and any surface needs for the next process, with how each one is measured.

  • Weight and floor load

    Ask why the larger 250A is listed lighter than the 250, and get foundation and floor-load figures for the version you choose.

  • Utilities and waste

    Get the cooling and filtration, air, power, foundation and unloading scope that comes with that version.

Sources: TDG NISSIN product page: 25-block polysilicon cropperNWSS-250 / NWSS-250A data sheet

04 · PVYard procurement analysis

Trial both versions on your own blocks

  1. Fix the configuration

    Agree version, block size, wire, fixture and finished-length drawing before any cutting starts.

  2. Check all 25 positions

    Measure both cut ends at every position in the load for geometry, chips and cracks.

  3. Time the whole cycle

    Count loading, cutting, removing the end pieces and unloading. Record accepted blocks and total silicon loss.

  4. Test faults and service

    Simulate a clamp or wire fault, see how half-cut blocks are kept apart from good ones, and check maintenance access in person.

Sources: TDG NISSIN product page: 25-block polysilicon cropperNWSS-250 / NWSS-250A data sheet

05 · PVYard procurement analysis

Questions buyers ask about the 25-block croppers

Why are the 250 and 250A on one page?

TDG NISSIN lists them as two columns of one data sheet, so they are compared here side by side.

Is the block length 300 mm or 400 mm?

The page text says 400 mm and the sheet says 300 mm for both versions. Get the figure for your order in writing before you sign.

Does the 27 kW version use less energy per good block?

The sheet lists connected power only. Request a measured consumption figure over a full cycle on your stock.

Sources: TDG NISSIN product page: 25-block polysilicon cropperNWSS-250 / NWSS-250A data sheet

TURN THIS INTO A CLEAR REQUEST

Ask about this product

Include the product-specific questions above and replace every bracket with your actual requirement. Save your edited text to your sourcing brief, then review it before submitting an enquiry. Saving a brief does not send it to a manufacturer.

Sources

Manufacturer information and our buying guidance are labelled section by section above. Each source below shows the date it was checked.

TDG NISSIN product page: 25-block polysilicon cropper ↗

Source check: 2026-10-11 · Describes head and tail cropping of 25 blocks and gives the 400 mm block length.

NWSS-250 / NWSS-250A data sheet ↗

Source check: 2026-10-11 · Chinese and English sheet with one column per version; ask which revision is current.

Report a correction · How we prepare listings

Compare equipment for a related task

These entries are in the same category; check each one's specifications and configuration.

Analytics preferences

Allow optional audience measurement? Your choice can be changed in the footer. Essential account cookies remain necessary for sign-in and forms.