Solar module laminator series
Suzhou SC-Solar Equipment Co., Ltd. ↗The SC Solar laminator handles the encapsulation step for PV modules. Its table lists three working areas, all 2700 mm wide and 8700, 9400 or 10000 mm long, with a working range up to 180 °C. Your module layout and encapsulation recipe decide which size and arrangement to quote.
Covers the whole laminator series. Each size and arrangement can differ in cycle time, utility demand and output, so ask for the figures of the one you are quoted.
General illustration of module assembly equipment, not a photograph of this model. Ask the manufacturer for current photographs and layout drawings of the configuration offered.
START WITH YOUR PRODUCTION TASK
Fix your module layout and the full load-to-unload cycle, then decide on layers and chambers. Take the larger working area only if your loading pattern fills it and the process meets your target. Ask SC Solar to confirm the chosen configuration, its cycle and the laminate results in writing.
SOURCE-LINKED DATA
Published specifications
Values below are published by the manufacturer, each with the date its source was checked. Ask for the figures that apply to your configuration and material in the quotation.
| Parameter | Published value | Source check |
|---|---|---|
| Working temperature | Room temperature to 180 °C | 2026-09-26 |
| Temperature uniformity | ±1.5 °C | 2026-09-26 |
| Temperature accuracy | ±1 °C | 2026-09-26 |
| Working areas in the catalogue | 2700*8700(mm), 2700*9400(mm), 2700*10000(mm) | Archived review: 2026-10-07 |
| Heating options | Oil heating / Electric heating | Archived review: 2026-10-07 |
| Transmission accuracy | ±3mm | Archived review: 2026-10-07 |
| Noise | ≤80dB | Archived review: 2026-10-07 |
01 · PVYard procurement analysis
Four choices in one laminator order
| Choice | Catalogue listing | Settle in the offer |
|---|---|---|
| Working area | 2700 × 8700, 9400 or 10000 mm. | Usable area, clearance and modules per load. |
| Layers and chambers | Single, double or triple layers; one to three chambers. | Which combination is installed, and its loading, vacuum, heating and release sequence. |
| Heating | Oil or electric. | Chosen system, site utilities and process control. |
| Temperature and yield figures | Series ratings, including ±1.5 °C uniformity and ±1 °C accuracy. | Sensor positions, stack recipe, defect limits and trial conditions. |
Source: SC Solar laminator product page
02 · PVYard procurement analysis
One full module cycle, step by step
Load your stack
Send module size and stack materials, and agree support, spacing and transfer clearances.
Run the agreed recipe
Get the settings and measurements that suit your encapsulant and module build.
Unload and inspect
Decide where laminate quality is checked and where rejected laminates go.
Repeat at production pace
Count loading, recovery, cleaning and changeover when you measure accepted output, since platen area alone gives no throughput figure.
Source: SC Solar laminator product page
03 · PVYard procurement analysis
Oil or electric heating
Site utilities
Put the utility schedules and extra equipment of the two heating options side by side. Energy use and installed cost vary from site to site, so ask SC Solar for figures that match yours.
Laminate results
Have both offers process the same module stack under one acceptance plan. Temperature uniformity describes the press, while a good laminate needs its own sample and inspection.
Source: SC Solar laminator product page
04 · PVYard procurement analysis
What to send with the enquiry and get back in writing
Module and loading
External dimensions, stack, modules per load and a layout drawing.
Chosen combination
Working area, layers, chambers and oil or electric heating named in the quotation.
Cycle demonstration
Agreed input condition, recipe, measured full cycle and laminate inspection, confirmed in writing.
Site and handover
Utilities, loading interfaces, maintenance clearance, records and the operating documents delivered with the machine.
Transmission and noise
The series lists ±3mm transmission accuracy and ≤80dB noise. Ask how both are measured on the configuration you buy.
Source: SC Solar laminator product page
TURN THIS INTO A CLEAR REQUEST
Ask about this product
Include the product-specific questions above and replace every bracket with your actual requirement. Save your edited text to your sourcing brief, then review it before submitting an enquiry. Saving a brief does not send it to a manufacturer.
Sources
Manufacturer information and our buying guidance are labelled section by section above. Each source below shows the date it was checked.
SC Solar laminator product page ↗
Source check: 2026-10-11 · Laminator family page with configuration options and the model table.
Compare equipment for a related task
These entries are in the same category; check each one's specifications and configuration.