EQUIPMENT MODEL

HORIS L12 · Tube LPCVD system

NAURA ↗

The HORIS L12 deposits oxide and polysilicon layers in a horizontal quartz tube, with separately controlled heating zones and gas fed in at several points along the tube. It suits cell makers building passivating contacts who need doped or undoped poly films.

NAURA presents the L12 for TOPCon, TBC and HTBC cells. Its published figures cover temperature, control accuracy, breakage and vacuum tightness; film thickness maps and quartz life figures come with a quotation.

General illustration of cell production equipment, not a photograph of this model. Ask the manufacturer for current photographs and layout drawings of the configuration offered.

START WITH YOUR PRODUCTION TASK

Before ordering, agree the exact layer, dopant and wafer load, fix the quartz and gas-inlet configuration, and ask NAURA to confirm in writing the film results and quartz life it will demonstrate under your recipe.

SOURCE-LINKED DATA

Published specifications

Values below are published by the manufacturer, each with the date its source was checked. Ask for the figures that apply to your configuration and material in the quotation.

The manufacturer has not published a complete specification table for this entry. Request the exact offered drawing and operating limits.

See sources and check dates ↓

01 · Manufacturer information

How the L12 spreads gas and heat along the tube

NAURA builds the L12 with independently controlled heating zones, several gas inlet positions and a choice of front or rear flow. The aim is an even deposition from the first wafer in the boat to the last. How well that works depends on the loaded tube, so ask for thickness results measured with a full boat of your wafers.

The named processes are oxide, polysilicon and phosphorus- or boron-doped polysilicon. NAURA also describes stronger quartz, longer consumable life and upgraded wearing parts. Each cell architecture runs its own deposition recipe, so give the supplier the exact stack you plan to make. Doped poly layers usually need a later anneal, and NAURA's horizontal HORIS D12 furnace lists annealing among its processes.

Source: NAURA Vacuum Tech HORIS L12 product page

02 · Manufacturer information

HORIS L12 published figures

HORIS L12 published figures
ItemNAURA figureWhat to agree for your order
Maximum temperature650°CYour operating recipe and where temperature is measured.
Temperature control±1°CController accuracy; film uniformity is a separate figure.
Wafer breakage≤0.01%Wafer thickness, sample size and which handling steps count.
Pressure rise≤1 Pa/minChamber condition, volume and the leak-test method.
Named layersOxide and doped/undoped polysiliconPrecursor, dopant and target film properties.

Source: NAURA Vacuum Tech HORIS L12 product page

03 · PVYard procurement analysis

Spell out the quartz and cleaning package

  • Quartz parts

    Get tube, inlet, boat and seal drawings for your load, plus alignment tolerances, the spare parts NAURA supports and any contamination limits.

  • Film data

    Ask for thickness, dopant and sheet-resistance spread across boat positions and over several batches, run on the recipe you agree.

  • Running cost

    Request cleaning and replacement intervals, the downtime each takes, what your own staff may service, and quartz life figures from similar processes.

Source: NAURA Vacuum Tech HORIS L12 product page

04 · PVYard procurement analysis

Accepting an L12: deposition and service in one test

  1. Fix the film

    Write down precursor, dopant, wafer size, incoming surface and the layer properties you need.

  2. Record the tube setup

    Log the inlet, quartz and boat configuration, then run temperature and leak-rate tests on the installed tool.

  3. Map the films

    Measure several positions across a full boat over repeated runs, reporting thickness, doping and cell results apart.

  4. Test a quartz change

    Include boat loading damage, cleaning, quartz replacement and a restart back to the saved recipe.

Source: NAURA Vacuum Tech HORIS L12 product page

05 · PVYard procurement analysis

Questions buyers ask about the HORIS L12

Does ±1°C mean the polysilicon will be uniform?

That figure describes the temperature controller. Film uniformity comes from measuring films grown in a loaded tube, so ask NAURA for those maps.

How many batches does the stronger quartz last?

NAURA describes longer life without a batch count. Ask for a figure tied to a recipe close to yours and put it in the contract.

Can one tube run both phosphorus and boron poly?

Treat them as two processes with their own chemistry, film targets and contamination controls, and have each one specified in writing.

Source: NAURA Vacuum Tech HORIS L12 product page

TURN THIS INTO A CLEAR REQUEST

Ask about this product

Include the product-specific questions above and replace every bracket with your actual requirement. Save your edited text to your sourcing brief, then review it before submitting an enquiry. Saving a brief does not send it to a manufacturer.

Sources

Manufacturer information and our buying guidance are labelled section by section above. Each source below shows the date it was checked.

NAURA Vacuum Tech HORIS L12 product page ↗

Source check: 2026-10-11 · Lists the L12 process range, its 650°C and ±1°C figures, breakage and pressure-rise limits, and shows the furnace.

Report a correction · How we prepare listings

Compare equipment for a related task

These entries are in the same category; check each one's specifications and configuration.

Analytics preferences

Allow optional audience measurement? Your choice can be changed in the footer. Essential account cookies remain necessary for sign-in and forms.