PV MANUFACTURING EQUIPMENT
My account中国工厂入驻 Create RFQ

EQUIPMENT SERIES

HORAD custom PV module line integration offering

Suzhou HORAD New Energy Equipment Co., Ltd. ↗

HORAD's R&D team plans a whole module line around one customer: where the machines go in the factory, which stations are used and how the line is balanced. This entry covers that integration job; each station has its own page.

HORAD describes the service and says it raises automation and efficiency and cuts manpower, with no line figures. Capacity, station list, staffing and acceptance terms are written into each project contract.

General illustration of module assembly equipment, not a photograph of this model. Ask the manufacturer for current photographs and layout drawings of the configuration offered.

START WITH YOUR PRODUCTION TASK

Use it if you want one supplier responsible for a full module line. Send your module BOM and plant limits, fix which stations and manual tasks are included, and accept the line on sustained good output, records and recovery from faults.

SOURCE-LINKED DATA

Published specifications

Values below are published by the manufacturer, each with the date its source was checked. Ask for the figures that apply to your configuration and material in the quotation.

The manufacturer has not published a complete specification table for this entry. Request the exact offered drawing and operating limits.

See sources and check dates ↓

01 · Manufacturer information

What HORAD takes on as integrator

HORAD's R&D team customizes semi-automatic or fully automatic lines to each customer's needs, covering factory layout, equipment deployment and line planning. HORAD says this improves automation and efficiency and reduces manpower. No numeric line specification or before-and-after comparison is given.

HORAD's station catalogue covers glass and film handling, string layup and joining, lamination, framing, junction-box work, labeling, test interfaces and packing. Several of those stations come in different configurations with process details still to settle. Line rate depends on your product, buffers and manual steps, so ask HORAD to quote a rate for your module rather than adding up station cycle times.

Source: HORAD PV module turnkey line product page

02 · PVYard procurement analysis

Turning the offer into a contract

Turning the offer into a contract
AreaWhat to defineWhy it matters
Product and processCell and module architecture, BOM, drawings and qualified materialsTwo modules of the same size can need different processes.
Station supplyOperations, options, tooling and exclusionsKeeps mounting adhesive, internal potting, handling and test scopes apart.
Layout and utilitiesInstalled machines, buffers, services and safe maintenance accessMachine footprints added together leave out buffers and aisles.
Manual workLoading, refills, inspection, boxing and fault recoveryStaffing follows from these tasks, whatever the automation level.
Controls and recordsInterlocks, module identity, recipe, test, grade and package linksTraceability has to hold across every handover between stations.
Acceptance and supportFAT/SAT samples, rate and yield methods, training, spares and change controlGives each party a measurable responsibility for the delivered line.

Source: HORAD PV module turnkey line product page

03 · PVYard procurement analysis

Brief to send HORAD

  • Module file

    Architecture, materials, drawings, your first product mix and the format changes you expect. Say who owns recipes and product qualification.

  • Plant file

    Floor space, access, floor load limits and utilities. Ask for an installed layout that shows buffers and maintenance access.

  • Output target

    What counts as good product, sustained rate, shift pattern and yield and rework limits. Ask for one rate figure for the integrated line.

  • Scope and service

    Equipment, software, commissioning, training and support, and who answers for each subcontractor and interface.

  • Acceptance terms

    Approved samples, measured process and module results and witnessed FAT and SAT records. Keep a list of quotation points and tick each off as HORAD answers it.

Source: HORAD PV module turnkey line product page

04 · PVYard procurement analysis

Accepting the integrated line

  1. Freeze the package

    Sign off module and BOM, stations and options, plant layout, utilities and the responsibility map.

  2. Prove critical stations

    Check process and module results on the selected equipment, each against its own station criteria.

  3. Run the line as a whole

    Measure sustained good output, manual work and rejects under set conditions, and check module identity at every handover.

  4. Test faults and changeovers

    Block the downstream flow, run out of material, change product and restart. Sign off recovery, training, spares, tooling and first-piece checks.

Source: HORAD PV module turnkey line product page

05 · PVYard procurement analysis

Module line integration questions

Does HORAD publish a line capacity?

No. The page describes custom lines and gives no full-line output figure.

Can I add station cycle times to get a line guarantee?

Line output depends on product and process, buffers, faults, manual work and what counts as a good module. Ask HORAD to confirm in writing a line figure on those terms.

Are software and recipes part of turnkey?

HORAD's short page leaves this open. Name each deliverable and the integration tests in the contract.

How does this differ from the layup machine page?

This one covers the line contract, the plant, interfaces and line acceptance. Each station's specs stay on its own page.

Source: HORAD PV module turnkey line product page

TURN THIS INTO A CLEAR REQUEST

Ask about this product

Include the product-specific questions above and replace every bracket with your actual requirement. Save your edited text to your sourcing brief, then review it before submitting an enquiry. Saving a brief does not send it to a manufacturer.

Sources

Manufacturer information and our buying guidance are labelled section by section above. Each source below shows the date it was checked.

HORAD PV module turnkey line product page ↗

Source check: 2026-10-11 · Short overview of HORAD's custom line design, layout and equipment deployment service.

Report a correction · How we prepare listings

Compare equipment for a related task

These entries are in the same category; check each one's specifications and configuration.

Analytics preferences

Allow optional audience measurement? Your choice can be changed in the footer. Essential account cookies remain necessary for sign-in and forms.